3) When switching off the siren, all alarms raised will not drive the siren, when
switching on the siren, the system alarm will drive the siren for 1 minute
except the SOS help caused. Default is then switched on.
4) When setting up the Report Time Gap, the system will periodically send “GSM
Alarm System in good working condition” to the first SMS Alert number. This
is very useful for long time use of the system. Default is 0. Meaning it will not
report the system condition.
5) If you enable the power failure alert function, the system will send an SMS
AC Power Failed 30Min” to the first SMS Alert numbers after the AC power
failed for 30minutes, if the power is recovered it will send an SMS “AC Power
is OK”. Default is then disabled.
6) There’s no delay for Stay Mode.
6.2.2.4 Advanced Setting
For example:
In South Africa, the country code is 0027, please note, do not write +27.
The user cell phone number is for example 082 123 4567 and has been assigned as
a SMS Alert number, the SIM Card number in the panel is for example 082 321 7654.
Problem 1: Alarm but the user hasn’t received the SMS Alert.
Solution: Please add the country code when you setup the 082 123 4567 as SMS
Alert number, using 0027821234567 instead of 0821234567.
Problem 2: The user number can receive the SMS Alert message from alarm panel,
but the alarm panel can not receive the commands from the user number.
Solution: Please add country code to the SIM card number in the alarm panel. Using
SMS commands to 0027823217654 instead of 0823217654.