PT2262 IC, and
incorrect Value;
3) Haven’t pulled out
wireless antenna;
4) Electromagnetic
interference;
5) The wireless receiver
in the panel with
problem.
Ohm of the PT2262 Wireless sensor;
3) Please pull out the wireless sensor
antenna;
4) Please install the wireless sensors or
alarm panel away electric appliances;
5) Please contact your distributors or
manufacturer to replace it
1) PIR Motion sensor
installation incorrect;
2) Used 24H zones or
SOS Zones or
Watchdog zone.
3) NC/NO/EOL is
incorrect.
1) Please see the PIR Motion sensor
installation user manual carefully;
2) Please check if any sensor assigned to
these special zones are incorrectly
activated;
3) Please check the detector NC/NO type
and NC/NO/EOL are correct and a 2.2K
resistor is in the un-use input ports.
Alarm without
SMS/
Alarm without
Dial/
No action
after send
SMS
command
1) GSM Operator
communication
protocol;
2) Haven’t setup SMS
Alert/Auto dial
Numbers.
3) Caps Lock letters in
the SMS Commands.
1) Please setup the SMS alert numbers;
2) Please see Page 15, the sample of the
setup of the telephone numbers;
3) Please check the commands with CAPS
LOCK and correct format.
4) Also, please change another GSM
operator SIMCard to test it.