12. Maintenance
1) If the Control Unit works, but the remote control and other sensors fail,
please check and change the battery.
2) If the remote control works, but the Control Unit fails to send SMS texts,
switch the power of Control Unit off and switch it on after one minute.
Test this system after another minute, or check that the settings are
correct and the GSM signals are strong enough.
3) If the Control Unit can run and sensors work, but cannot send SMS texts,
please change the SIM Card to check it.
13. Warranty
1) This system is warranted to be free of defects in material and
workmanship for one year from the date of purchase.
2) This warranty does not extend to any defect, malfunction or failure
caused by abuse or misuse by the Operating Instructions.
15. Trouble Shooting Guide
GSM Module
initialization
failed
1) Backup battery with low
voltage;GSM Module
connection loose in
transportation;
2) GSM Signal is too
weak
1) Please contact the AC Power;
2) Please take the panel to a mobile phone
repairmen store, ask the engineer to
check the GSM Module socket and the
GSM Module connection;
3) Please change another position to install
the alarm panel.
1) Backup battery with
low voltage
1) When the backup battery voltage is lower
than 3.7V, the panel will alert by buzzer
sounds. Please contact the AC Power.
Wireless
Sensor
transmission
1) Wireless sensor with
low voltage
2) Wireless sensor used
1) Please replace the battery of the wireless
sensor, usually once /year;
2) Please correct the resistor value to 3.3M